Air conditioning & HVAC

Job cards for air conditioning & hvac companies.

Installs, services, repairs and VRV/VRF — with vacuum, pressure and temperature readings on every card. Techs fill them in on their phones — even with no signal.

Start free trial

Ready-made checklists

☐ = tick box   ✎ = the tech types a reading, serial number or certificate number. Every job also records arrival time, before/after photos, materials and the client's signature.

Aircon installation

  • Indoor unit make, model and serial no.
  • Outdoor unit make, model and serial no.
  • Refrigerant type (R32 / R410A / other)
  • Site survey agreed with client: indoor and outdoor positions, pipe route, drain route
  • Wall brackets / outdoor stand secured, unit level, anti-vibration pads fitted
  • Clearances to manufacturer spec (indoor top/sides, outdoor airflow)
  • Pipework flared/brazed correctly, nitrogen used when brazing
  • Pipes and cable insulated and secured, trunking fitted and sealed
  • Wall penetration sealed and weatherproofed
  • Pressure test with nitrogen, no drop over test period
  • Test pressure (kPa) and duration
  • Vacuum to below 500 microns, decay test held
  • Final vacuum (microns)
  • Refrigerant released / topped up for pipe length
  • Refrigerant added (kg)
  • Drain fall correct and water test done, no leaks
  • Dedicated circuit, correct breaker size, isolator within reach of outdoor unit
  • Electrical connections tight, earth connected
  • Unit run in cool and heat for at least 15 minutes
  • Supply air temperature (°C)
  • Return air temperature (°C)
  • Running current (A)
  • Remote paired, time set, client shown how to use it and clean filters
  • Site cleaned, packaging removed
  • Warranty registration details recorded

Aircon service

  • Unit make, model and serial no.
  • Filters removed, washed and refitted
  • Indoor coil cleaned (coil cleaner / sanitiser)
  • Blower wheel and fan cleaned
  • Drain tray and drain line flushed, pump tested if fitted
  • Outdoor coil cleaned, debris cleared around unit
  • Fan blades and motor checked
  • Electrical connections checked and tightened
  • Capacitor checked
  • Suction pressure
  • Running current (A)
  • Supply air temperature (°C)
  • Return air temperature (°C)
  • Remote and display working, no error codes
  • Faults found / recommendations

Aircon repair / fault

  • Fault reported by client
  • Error code(s) shown
  • Power supply, breaker and isolator checked
  • Fault found
  • Parts replaced (with part numbers)
  • Leak test done if refrigerant was low
  • Refrigerant added (kg), if any
  • Unit tested and running normally
  • Quote needed for further work

VRV / VRF service

  • System / outdoor unit model and serial no.
  • Number of indoor units serviced
  • Error history read from system
  • Outdoor unit coils cleaned, fans checked
  • Indoor unit filters cleaned, drains checked
  • Communication wiring and addressing checked
  • High and low pressures
  • Outdoor ambient temperature (°C)
  • Central controller / BMS interface checked
  • Oil and refrigerant levels within spec
  • Recommendations

Extraction & ventilation

  • Fan type, model and location
  • Fan running, correct direction, no vibration
  • Belts / bearings checked (if fitted)
  • Filters and grilles cleaned
  • Ducting and flexible connections checked for leaks
  • Controls / timers / sensors working
  • Airflow reading (if measured)

Use these checklists from today.

Change any line, add your own, or build new job types.

Start free trial