Solar & backup power

Job cards for solar & backup power companies.

PV and hybrid installs, inverter and battery services, UPS and generators — serial numbers and readings included. Techs fill them in on their phones — even with no signal.

Start free trial

Ready-made checklists

☐ = tick box   ✎ = the tech types a reading, serial number or certificate number. Every job also records arrival time, before/after photos, materials and the client's signature.

Solar / hybrid installation

  • Inverter make, model and serial no.
  • Battery make, model, capacity (kWh) and serial no(s).
  • Panels — make, watts each, quantity, strings
  • Roof inspected; mounting rails fixed to rafters, roof sealed at every penetration
  • Panels earthed, frames bonded
  • DC isolator and DC surge protection fitted
  • AC isolator, AC surge protection and changeover / bypass fitted
  • Battery fused / breaker protected, cables sized correctly
  • String open-circuit voltage (V) per string
  • String short-circuit current (A) per string
  • Polarity checked before connecting inverter
  • Inverter settings: grid mode, battery type, charge limits, export limit
  • Inverter NRS 097-2-1 certificate available (needed for municipal registration)
  • Monitoring app set up and linked to client's account
  • Tested on grid, on battery (grid off) and generator input (if any)
  • Labels and warning signs fitted at DB, inverter and isolators
  • Client shown how to use the app and isolate the system
  • COC number (electrical) and SSEG application status

Solar / inverter service

  • Inverter and battery serial nos.
  • Error / fault history from inverter
  • Panels inspected and cleaned (if agreed)
  • Mounting and roof penetrations checked
  • DC and AC connections checked and torqued
  • Inverter fans and vents cleaned
  • Battery state of health (%)
  • Firmware up to date
  • Daily generation vs expected
  • Recommendations

UPS service

  • UPS make, model, kVA and serial no.
  • Battery type, quantity and install date
  • Load assessed against UPS rating
  • Load (%)
  • Battery test / runtime test done
  • Runtime at current load (min)
  • Bypass and changeover tested
  • Alarms and display working, no faults
  • Fans and vents cleaned

Generator service

  • Generator make, model, kVA and serial no.
  • Running hours
  • Oil level and condition checked / changed
  • Oil, fuel and air filters checked / replaced
  • Coolant level checked (if water cooled)
  • Battery and charger checked
  • Battery voltage (V)
  • Belts and hoses checked
  • Fuel level and fuel condition checked
  • Changeover (ATS) tested with mains off
  • Run under load
  • Output voltage and frequency (V / Hz)
  • No leaks or unusual noise
  • Next service due (hours or date)

Use these checklists from today.

Change any line, add your own, or build new job types.

Start free trial